Residential Electrical Load Calculator
Estimate a home's electrical service load with the NEC 220.82 optional method. Get total VA, amps, and a recommended panel size with a full breakdown.
Estimate the service load
Enter the dwelling details below. The calculation follows the NEC 220.82 optional method and updates as you type.
The Home
General lighting is figured at 3 VA per square foot; each small-appliance and laundry circuit adds 1,500 VA.
Livable area, per the outside dimensions
Kitchen/dining receptacle circuits
Fixed Appliances
Nameplate ratings in VA. Edit to match the actual equipment, or zero out anything the home does not have.
Typical: 12,000 VA
Typical: 4,500 VA
Typical: 5,000 VA
Typical: 1,200 VA
Typical: 1,500 VA
Typical: 900 VA
Typical Level 2: 7,200 VA
Pool pump, hot tub, etc.
Heating & Cooling
Enter both loads; the larger of the two is applied at 100%. (This simplifies NEC 220.82(C), which has separate factors for heat pumps and staged electric heat.)
Furnace, baseboards, or heat pump + supplemental heat
Air conditioner or heat pump in cooling
Enter the floor area to calculate the service load
You'll get total VA, amps, a recommended service size, and a full breakdown.
This is an estimate, not a permit document
Figures follow the NEC 220.82 optional method for a single dwelling, with the heating/cooling comparison simplified. The Canadian CEC Section 8 calculation differs. Final service and conductor sizing must be done by a licensed electrician and approved by your local AHJ.